standar | IEC/EN60898-1 | ||
Listrik Fitur | Dipeunteun ayeuna Dina | A | 1,2,4,6,10,16,20,25,32,40,50,63 |
Kutub | P | 1,2,3.4 | |
tegangan dipeunteun Ue | V | AC 240/415 | |
tegangan insulasi Ui | V | 500 | |
Frékuénsi dipeunteun | HZ | 50/60 | |
Kapasitas pegatna dipeunteun | A | 3000.4500(2~40A/6000) | |
Dipeunteun dorongan tahan tegangan (1.2/50) Uimp | V | 4000 | |
Tegangan uji diéléktrik dina ind. Frek. keur 1 mnt | KV | 2 | |
Gelar polusi | 2 | ||
Ciri pelepasan termo-magnétik | B, C, D | ||
Fitur mékanis | Kahirupan listrik | t | 4000 |
Kahirupan mékanis | t | 10000 | |
Gelar panyalindungan | IP20 | ||
Suhu rujukan pikeun netepkeun unsur termal | ℃ | 30 | |
Suhu ambient (kalayan rata-rata poean ≤35 ℃) | ℃ | -5 ~ + 40 (Aplikasi khusus mangga tingal koreksi kompensasi suhu) | |
Suhu neundeun | ℃ | -25~+70 | |
Pamasangan | Jenis sambungan terminal | kabel / Pin-tipe busbar | |
Ukuran terminal luhur / handap pikeun kabel | mm²/AWG | 25/18-3 | |
Ukuran terminal luhur / handap pikeun busbar | mm²/AWG | 25/18-3 | |
Torsi tightening | N*m/ ln-lbs | 2/18 | |
Pamasangan | Dina rel DIN EN 60715(35mm) ku alat klip gancang | ||
Sambungan | Ti luhur jeung handap |