Compressor hawa Technoloty hususParameter Jeung Mode (WQC)
Tipe | Kakuatan | Voltaseu | Dipeunteun ayeuna | Bagian relay termal disaluyukeun wengkuan |
WQC-12 | 0,75KW | 380V | 2.1A | 1.7-2.5A |
WQC-12 | 1.1KW | 380V | 2.5A | 2-3A |
WQC-12 | 1,5KW | 380V | 3.6A | 2.8-4.4A |
WQC-12 | 2.2KW | 380V | 5A | 4-6A |
WQC-12 | 3KW | 380V | 6.6A | 5.2-8A |
WQC-32 | 4KW | 380V | 9A | 7-11A |
WQC-32 | 5,5KW | 380V | 11A | 9-13A |
WQC-32 | 7,5KW | 380V | 15A | 12-18A |
WQC-32 | 11KW | 380V | 22A | 20-32A |
WQC-50 | 15KW | 380V | 30A | 28-45A |
WQC-50 | 18,5KW | 380V | 37A | 40-63A |
WQC-65 | 18,5KW | 380V | 37A | 40-63A |
WQC-85 | 22KW | 380V | 44A | 40-63A |
WQC-95 | 30KW | 380V | 60A | 53-85A |
Tipe | Kontaktor | relay termal baku | Kontrol kakuatan motor (KW) | Arus dipeunteun (A) | ||||
Tipe | Disetél ayeuna | 220V | 380V | 500V | 220V | 380V | ||
QCX5-9 | CJX5-9 | JRS-5-12/Z | 3.6A | 0.75 | 1.5 | 2.2 | 11 | 9 |
QCX5-9 | CJX5-9 | JRS-5-12/Z | 5A | 1.1 | 2.2 | 3 | 11 | 9 |
QCX5-9 | CJX5-9 | JRS-5-12/Z | 6.6A | 1.5 | 3 | 3.7 | 11 | 9 |
QCX5-9 | CJX5-9 | JRS-5-12/Z | 9A | 2.2 | 4 | 5.5 | 11 | 9 |
QCX5-12 | CJX5-12 | JRS-5-12/Z | 3.6A | 0.75 | 1.5 | 2.2 | 13 | 12 |
QCX5-12 | CJX5-12 | JRS-5-12/Z | 5A | 1.1 | 2.2 | 3 | 13 | 12 |
QCX5-12 | CJX5-12 | JRS-5-12/Z | 6.6A | 1.5 | 3 | 3.7 | 13 | 12 |
QCX5-12 | CJX5-12 | JRS-5-12/Z | 9A | 2.2 | 4 | 5.5 | 13 | 12 |
QCX5-12 | CJX5-12 | JRS-5-12/Z | 11A | 3 | 5.5 | 7.5 | 13 | 12 |
QCX5-22/11 | CJX5-22/11 | JRS-5-20/F | 11A | 3 | 5.5 | 7.5 | 22 | 22 |
QCX5-22/11 | CJX5-22/11 | JRS-5-20/F | 15A | 3.7 | 7.5 | 9 | 22 | 22 |
QCX5-22/22 | CJX5-22/22 | JRS-5-20/F | 11A | 3 | 5.5 | 7.5 | 22 | 22 |
QCX5-22/22 | CJX5-22/22 | JRS-5-20/F | 15A | 3.7 | 7.5 | 9 | 22 | 22 |
QCX5-32 | CJX5-32 | JRS-5-20/F | 19A | 5.5 | 11 | 11 | 30 | 30 |
QCX5-32 | CJX5-32 | JRS-5-20/F | 22A | 5.5 | 11 | 11 | 30 | 30 |
QCX5-40 | CJX5-40 | JRS-5-20/F | 19A | 5.5 | 11 | 11 | 40 | 40 |
QCX5-40 | CJX5-40 | JRS-5-20/F | 22A | 5.5 | 11 | 11 | 40 | 40 |
QCX5-40 | CJX5-40 | JRS-5-20/F | 29A | 7.5 | 15 | 18.5 | 40 | 40 |
QCX5-40 | CJX5-40 | JRS-5-20/F | 35A | 9 | 18.5 | 22 | 40 | 40 |
Dimensi jeung Pamasangan Diménsi
■ Starter tiasa lami sareng teu tiasa dianggo relay termal. Frékuénsi tiasa 600 kali / jam dina waktu anu singget sareng sababaraha kali damel;
■ Atraksi coil reliably tiasa dianggo nalika 85% ~ 105% dipeunteun tegangan, Hayu urang dileupaskeun tegangan kira 40 ~ 55% dipeunteun tegangan;
■ The kontak starter dina frékuénsi operasi nyaéta 600 / jam, telegram sirkular terus mingpin forthe istighfar 40%.Puts ngaliwatan arus nominal nempatkeun ngaliwatan, nalika separation faktor 0,35, Ieu hirup listrik teu leuwih handap 640.000 kali;
■ Kahirupan mékanis starter nyaéta 3 juta kali;
■ kontak bantu starter urang, éta ayeuna nominal 5A;
■ The relay termal boga organisasi santunan hawa, Bisa nyaimbangkeun hawa nu disababkeun ku parobahan tegangan sabudeureun suhu;
■ The relay termal overload nyaeta kalawan stipulations. Pikeun ningali handap.